PP-30B
PUMP FOR PIGGING / CHEMICAL CLEANING
PUMP FOR PIGGING / CHEMICAL CLEANING
Offshore
Diesel
MUST BE CONNECTED TO SEPERATE MOTOR UNIT (PP-30A), (see separate datasheets for technical information)
Two-piece unit, where the engine and pump has to be connected via a drive shaft, hydraulic and diesel hoses (Diesel tank is located at pump unit).
- The unit is driven at a fixed RPM. Pressure/flow can be regulated by using a 5 step gearbox.
- The unit is remote-operated, but can also be driven from local panel.
- To change plunger sizes, the fluid-end has to be changed at our workshop. This can also be done in the field, when stated in order (then i.a. bolt tensioning equipment will be included in the delivery).
4" FLUID-END - EXTENDED DUTY RATING (Max usage 12-24hrs/day):
1. gear 2. gear 3. gear 4. gear 5. gear
Q max. : 532 l/min. 787 l/min. 1050 l/min. 1272 l/min. 1272 l/min.
P max. : 207 bar 165 bar 131 bar 110 bar 110 bar
4" FLUID-END - INTERMITTENT DUTY RATING (Max usage 4 h/day at max 80%, 5-10 min at 100%):
1. gear 2. gear 3. gear 4. gear 5. gear
Q max. : 532 l/min. 787 l/min. 1050 l/min. 1564 l/min. 2097 l/min.
P max. : 348 bar 236 bar 176 bar 118 bar 82 bar
2-3/4" FLUID-END - EXTENDED DUTY RATING (Max usage 12-24hrs/day):
1. gear 2. gear 3. gear 4. gear 5. gear
Q max. : 197 l/min. 292 l/min. 389 l/min. 472 l/min. 472 l/min.
P max. : 524 bar 489 bar 352 bar 317 bar 317 bar
2-3/4" FLUID-END - INTERMITTENT DUTY RATING (Max usage 4 h/day at max 80%, 5-10 min. at 100%):
1. gear 2. gear 3. gear 4. gear 5. gear
Q max. : 197 l/min. 292 l/min. 389 l/min. 580 l/min. 786 l/min.
P max. : 1027 bar 689 bar 541 bar 349 bar 269 bar