Dimensjoner

  • Lengde(mm):
    3170
  • Bredde(mm):
    2410
  • Høyde(mm):
    3000
  • Vekt (kg):
    8900
  • Løfting/ Transport:
    10’ Offshore container with forklift channels and lifting slings in accordance to DNV 2.7-1

Byggeår

  • Byggeår:
    2004

Bruksområde / Sertifisering

  • Onshore/offshore:

    Offshore

  • Standard:
    Offshore, Zone II, Norsok Z-015, ATEX
  • Drift (Elektrisk/Diesel):

    Diesel

Flow / Trykk / Volum

  • Hz v Q-maks måling:
    N/A (Diesel)
  • Q-max (l/min):
    2260
  • Hz v P-maks måling:
    N/A (Diesel)
  • P-max (bar):
    351
  • Flowrate1:
    1737 ltr/min @ 82 bar (5" Fluid-end@5. gear) INDUSTRIAL DUTY RATING
  • Flowrate2:
    1291 ltr/min @ 117 bar (5" Fluid-end@3. gear) INDUSTRIAL DUTY RATING
  • Flowrate3:
    654 ltr/min @ 174 bar (5" Fluid-end@1. gear) INDUSTRIAL DUTY RATING
  • Diesel tankvolum (ltr):
    1200
  • Dieselforbruk (ltr/time):
    120

Tilkoblinger

  • Tilkopling inn:
    4" 150#
  • Tilkopling ut:
    2" 1502 Weco Female

Pumpe(r)

  • Pumpe1 (type):
    Garden Denver OPI600 triplex

Motor(er)

  • Motor1 (type):
    MUST BE CONNECTED TO SEPERATE MOTOR UNIT (PP-24A)

Strømforsyning

  • (A):
    10-16

Annen informasjon

  • Utstyr / Funksjoner:

    MUST BE CONNECTED TO SEPERATE MOTOR UNIT (PP-24A), (see separate datasheets for technical information)

    Two-piece unit, where the engine and pump has to be connected via a drive shaft, hydraulic and diesel hoses (Diesel tank is located at pump unit).

    - The unit is driven at a fixed RPM. Pressure/flow can be regulated by using a 5 step gearbox.

    - The unit is remote-operated, but can also be driven from local panel.

    - To change plunger sizes, the fluid-end has to be changed at our workshop. This can also be done in the field, when stated in order (then i.a. bolt tensioning equipment will be included in the delivery).

    - 2-1/2" 3" and 4" plungers can also be used, these are not stock items.

    5" FLUID-END - INDUSTRIAL DUTY RATING (Max usage 8-12hrs/day):

    1. gear 2. gear 3. gear 4. gear 5. gear

    Q max. : 654 l/min. 967 l/min. 1291 l/min. 1737 l/min. 1737 l/min.

    P max. : 174 bar 157 bar 117 bar 87 bar 82 bar

    5" FLUID-END - INTERMITTENT DUTY RATING (Max usage 5-10 min.):

    1. gear 2. gear 3. gear 4. gear 5. gear

    Q max. : 284 l/min. 566 l/min. 1132 l/min. 1698 l/min. 2260 l/min.

    P max. : 351 bar 328 bar 164 bar 109 bar 82 bar

    2-3/4" FLUID-END - INDUSTRIAL DUTY RATING (Max usage 8-12hrs/day):

    1. gear 2. gear 3. gear 4. gear 5. gear

    Q max. : 198 l/min. 292 l/min. 390 l/min. 525 l/min. 525 l/min.

    P max. : 579 bar 521 bar 390 bar 289 bar 289 bar

    2-3/4" FLUID-END - INTERMITTENT DUTY RATING (Max usage 5-10 min.):

    1. gear 2. gear 3. gear 4. gear 5. gear

    Q max. : 85 l/min. 203 l/min. 340 l/min. 510 l/min. 765 l/min.

    P max. : 1161 bar 1161 bar 689 bar 460 bar 300 bar