Dimensjoner

  • Lengde(mm):
    3120
  • Bredde(mm):
    2320
  • Høyde(mm):
    2705
  • Vekt (kg):
    4600
  • Løfting/ Transport:
    Frame with forklift channels and lifting slings. DNV 2.7-1. Tare: 4600 Kg - Payload: 3650 kg - MGW: 8000 kg
  • Sertifikater / Serie Nr.:
    NV-HRS—98-35-18893

Byggeår

  • Byggeår:
    1993
  • Oppgradert/ombygd (år):
    2015

Bruksområde / Sertifisering

  • Onshore/offshore:

    Offshore

  • Standard:
    Zone 2, Z-015

Flow / Trykk / Volum

  • Q-maks (m3/min):
    20.8
  • Maks vakum:
    0,9 Bar Vacuum

Tilkoblinger

  • Tilkopling inn:
    1 ea. 4” Camlock male Inlet watercoupling/drive : 1” klokopling (minimum 2 Bar with freshwater)
  • Tilkopling ut:
    1 ea. 4" Camlock female Outlet watercoupling: 1” Camlock female

Pumpe(r)

  • Pumpe1 (type):
    Samson Pumps V21R45E1 (KS1025)
  • Pumpe1 (ser. nr.):
    0407604447-2

Motor(er)

  • Motor1 (type):
    WEG 225S/M-4 Motor 1 EEx de IIB T4 IP55 (Cert. No: CESI 01 ATEX 099)
  • Motor1 (ser. nr.):
    0A82646

Drift

  • Drift (Elektrisk/Luft):
    Electrical
  • Sikring (antall):
    1
  • Sikring (A):
    63
  • Strøm tilkopling 1:
    380-415 VD
  • (Hz):
    50
  • (kW):
    37
  • (A):
    68,3-65,4
  • Strøm tilkopling 2:
    660-690 VY
  • (Hz):
    50
  • (kW):
    37
  • (A):
    39,3-37,9
  • Strøm tilkopling 3:
    400 VD
  • (Hz):
    60
  • (kW):
    37
  • (A):
    66,7
  • Strøm tilkopling 4:
    440 VD
  • (Hz):
    60
  • (kW):
    42
  • (A):
    66,9
  • Strøm tilkopling 5:
    460 VD
  • (Hz):
    60
  • (kW):
    42
  • (A):
    64,8
  • Starter:
    2 ea. Technor Atex ERSA 2853 (Ser.No: 000217 / 000213) EEx de IIB T4 IP65/66 Cert. No: INERIS 04ATEX0009X

Annen informasjon

  • Utstyr / Funksjoner:

    Recom. back-up fuse :

    660V-690V: 63A

    400v-480V: 63A "slow" fuse (D-characteristic, outlet for motorstarter, circuitbreaker)

    - Light

    - Pressure Gauge

    - Transition 4” camlock male/male

    Must be connected to a mud/collecting tank (ship) standard volume 2700 liters . Connection exhaust can also be used to blow with, transition 4” camlock male/male located inside the unit.