Dimensjoner

  • Lengde(mm):
    2990
  • Bredde(mm):
    2320
  • Høyde(mm):
    2470
  • Vekt (kg):
    2300
  • Løfting/ Transport:
    Frame with forklift channels and lifting slings. DNV 2.7-1 /DNV 2.7-2 Tara 2300 Kg - Payload 5700 Kg - MGW 8000 Kg
  • Sertifikater / Serie Nr.:
    NV-HRS-01-07/29354 / 57364-001 / VS-20

Byggeår

  • Byggeår:
    2001
  • Oppgradert/ombygd (år):
    2009

Bruksområde / Sertifisering

  • Onshore/offshore:

    Offshore

  • Standard:
    Zone 1, Z-015

Flow / Trykk / Volum

  • Q-maks (m3/min):
    24.4
  • Maks vakum:
    0,9 Bar Vacuum

Tilkoblinger

  • Tilkopling inn:
    1 ea. 4” Camlock male
  • Tilkopling ut:
    1 ea. 4" Camlock female

Pumpe(r)

  • Pumpe1 (type):
    Hibon ALPHA 20+
  • Pumpe1 (ser. nr.):
    49030766

Motor(er)

  • Motor1 (type):
    Brook Crompton WU-EF225SN IP55 EEx de IIB T4 (Cert. No: Bas.no.Ex97D1111X)
  • Motor1 (ser. nr.):
    GX032148

Drift

  • Drift (Elektrisk/Luft):
    Electrical
  • Sikring (antall):
    1
  • Sikring (A):
    63
  • Strøm tilkopling 1:
    380-415 VD
  • (Hz):
    50
  • (kW):
    37
  • (A):
    69-63
  • Strøm tilkopling 2:
    400 VD
  • (Hz):
    60
  • (kW):
    35
  • (A):
    62
  • Strøm tilkopling 3:
    440-480 VD
  • (Hz):
    60
  • (kW):
    43
  • (A):
    70-64
  • Strøm tilkopling 4:
    660-690 VY
  • (Hz):
    50
  • (kW):
    37
  • (A):
    40-38
  • Strøm tilkopling 5:
    660-690 VY
  • (Hz):
    60
  • (kW):
    33-35
  • (A):
    39
  • Starter:

    Gexys AS (Ser. No: 2009/3406/1)

    EEx de IIC T6 IP66 (Cert. Nr: 09 ATEX 52184X)

    690V 63A Nemko No: 93.381

Annen informasjon

  • Utstyr / Funksjoner:

    Recom. back-up fuse :

    660V-690V: 63A

    400v-480V: 63A "slow" fuse (D-characteristic, outlet for motorstarter, circuitbreaker)

    - Light

    - Gauge

    Must be coupled to vacuumtank (VS-20B), and an optional mud-tank (skip). Standard volume of skip is 2700 litres.

    Inlet coupling can also be used to blow with, but do NOT use exhaust coupling to blow with, this line does not have a safetyvalve.