Dimensjoner

  • Lengde(mm):
    1060
  • Bredde(mm):
    580
  • Høyde(mm):
    940
  • Vekt (kg):
    330
  • Løfting/ Transport:
    Frame with forklift channels

Bruksområde / Sertifisering

  • Onshore/offshore:

    Onshore

Type

  • Produsent:
    Pall
  • Modell:
    HNP 021
  • Serienr.:
    HNPE 524

Flow / Trykk / Volum

  • Q-max (l/min):
    20
  • P-max (bar):
    7
  • Min.viskosiet (cst):
    10
  • Maks. viskositet (cst):
    700
  • Maks. temp. (GrC):
    70

Tilkoblinger

  • Tilkopling inn:
    1 ea. 1" BSP
  • Tilkopling ut:
    1 ea. 1" BSP

Drift

  • Drift (Elektrisk/Luft):

    Elektrisk

  • Sikring (antall):
    1
  • Sikring (A):
    16
  • Strøm tilkopling 1:
    230 V, 1 phase
  • (Hz):
    50/60

Filter

  • Filter inn:

    Filter in: 1 ea. Washable strainer

    Coalescer filter element: 1 ea. Pall HS 74499

    Oil separator filter (Primary): 1 ea. Pall HS 75390

    Oil separator filter (Secondary): 1 ea. Washable filter

  • Filter ut:
    Filter element out: 1 ea. Pall HC 9100 FKS 8H Ventilating filter on tank : 1 ea. Pall HC 0293 SEE5

Annen informasjon

  • Utstyr / Funksjoner:

    Oil Fire point : Min. 93ºC

    To dry up the oil, the working temperature ought to be between 40-60ºC to achieve the best efficiency.

    Example: at 25ºC the dry up is approx. 6 ltr/24 hours, at 60ºC the dry up is approx. 40 ltr/24 hours.