Dimensjoner

  • Lengde(mm):
    5800
  • Bredde(mm):
    2438
  • Høyde(mm):
    2805
  • Vekt (kg):
    14900
  • Løfting/ Transport:
    Frame with forklift channels and lifting devices. DNV 2.7-1 Ref. cert. / Ser. no. frame : 68961 / PP-33

Byggeår

  • Byggeår:
    2007

Bruksområde / Sertifisering

  • Onshore/offshore:

    Offshore

  • Standard:
    Norsok Z-015, Type: G Zone 2, ATEX II3G Eex de IIA T3. 83 dB(A)
  • Drift (Elektrisk/Diesel):

    Diesel

Flow / Trykk / Volum

  • Hz v Q-maks måling:
    N/A (Diesel)
  • Q-max (l/min):
    6666
  • Hz v P-maks måling:
    N/A (Diesel)
  • P-max (bar):
    28
  • Flowrate1:
    Pump Alternative 2: 188 ltr/min @ 1000 bar
  • Flowrate2:
    Pump Alternative 3: 613 ltr/min @ 300 bar
  • Flowrate3:
    Pump Alternative 4: 2500 bar
  • Diesel tankvolum (ltr):
    700
  • Dieselforbruk (ltr/time):
    120

Tilkoblinger

  • Tilkopling inn:
    8” 150# RF
  • Tilkopling ut:
    4” 300# RF

Pumpe(r)

  • Pumpe1 (type):
    KSB Multitec MTC, A150/04-12.1 30.63
  • Pumpe1 (ser. nr.):
    9971141794/000200/01

Motor(er)

  • Motor1 (type):
    Deutz BF8M1015MC 590 HK
  • Motor1 (ser. nr.):
    9167493

Strømforsyning

  • Sikring (antall):
    1
  • Sikring (A):
    16
  • Strøm tilkopling 1:
    230V
  • (Hz):
    50/60
  • (A):
    10-16

Annen informasjon

  • Utstyr / Funksjoner:

    PUMP ALTERNATIVE 2 (specify with order)

    Kamat K-3500-A, K35036 (Serial no.: 151615/4)

    Q max: 188 ltr/min

    P max: 1000 bar

    Connection in: 2” Fire coupling

    Connection out: M36

    Connection Bypass out: 1" claw coupling

    PUMP ALTERNATIVE 3 (specify with order)

    Kamat K-3500-A, K35065M

    Q max: 613 ltr/min

    P max: 300 bar

    Connection in: 2” Fire coupling

    Connection out: 2" BSP

    PUMP ALTERNATIVE 4 (specify with order)

    Conversion set for Kamat pump

    Q max: 70 ltr/min

    P max: 2500 bar

    Connection in: 2” Fire coupling

    Connection out: 9/16HP Autoclave female

    Connection Bypass out: 1" claw coupling

    Fixed fire extinguiser PEFS Foam.

    Fire extinguisher 12kg.

    - Filter feed water : Washable strainer

    - Pressure gauge at pressure side

    - Pressure and vacuum gauge on suction side.

    - Reduction gear and air controlled clutch.

    - Heater and emergency light.

    - Signal to platform by: Fire, gas and common cause failure

    Air/Diesel supply closes if

    - Engine overspeed

    - Protective guard on pump

    - High exhaust temperature

    - Emergency stop from control room

    - High coolant temperature

    - Emergency stop

    - Low oil pressure

    - Fire alarm

    - Low air pressure

    - 10% Lel Gas alarm