Dimensjoner

  • Lengde(mm):
    3130
  • Bredde(mm):
    2437
  • Høyde(mm):
    3036
  • Vekt (kg):
    10050
  • Løfting/ Transport:
    10’ Offshore ISO container with forklift channels and lifting slings in accordance to DNV 2.7-1 . Can be stacked in height with use of ISO locks Ref.cert. / Ser. no. frame : PP-119B / HPP-21/2

Byggeår

  • Byggeår:
    2010

Bruksområde / Sertifisering

  • Onshore/offshore:

    Offshore

  • Standard:
    Offshore Zone 2, Norsok Z-015 ATEX, II 3G IIA T3
  • Drift (Elektrisk/Diesel):

    Diesel

Flow / Trykk / Volum

  • Hz v Q-maks måling:
    N/A (Diesel)
  • Q-max (l/min):
    2065
  • Hz v P-maks måling:
    N/A (Diesel)
  • P-max (bar):
    916
  • Flowrate1:
    2065 ltr/min @ 193 bar (4,5" plunger)
  • Flowrate2:
    950 ltr/min @ 410 bar (4,5" plunger)
  • Flowrate3:
    475 ltr/min @ 820 bar (4,5" plunger)
  • Diesel tankvolum (ltr):
    1200
  • Dieselforbruk (ltr/time):
    280

Tilkoblinger

  • Tilkopling inn:
    2 ea. 6” 150# Ansi
  • Tilkopling ut:
    2 ea. 2" Fig 1502 Female

Pumpe(r)

  • Pumpe1 (type):
    Gardner Denver GD-2250 Triplex pump. Standard Plunger 4,5", other sizes on request.
  • Pumpe1 (ser. nr.):
    Fluid End Prod.no: 1094THD2039 / Serial no.GO 35826

Motor(er)

  • Motor1 (type):
    MUST BE CONNECTED TO SEPERATE MOTOR UNIT (PP-119A)

Strømforsyning

  • (A):
    10-16

Annen informasjon

  • Utstyr / Funksjoner:

    MUST BE CONNECTED TO SEPERATE MOTOR UNIT (PP-119A), (see separate datasheets for technical information)

    Two-piece unit, where the engine and pump has to be connected via a drive shaft, hydraulic and diesel hoses.

    Diesel level must be limited to 600 liters for offshore use.

    Feed water pressure: Minimum 3,5 bar at full flow on triplex pump.

    LIMITATIONS

    80% load is 960 HHP@ 2100 rpm, can be used for 50% of the duty cycle or 6 out of every 12 hours.

    70% load is 840 HHP @ 2100 rpm. Operation below this can be used cyclic continuous.

    100% load is 1150 HP @ 2100 rpm, Can be used for maximum one hour. The following hour has to be below

    70% (840 HHP @ 2100 rpm)

    If the speed is lowered to 1800 rpm, the full load is lowered to 1040 HHP.

    80% load is 830 HHP@ 1800 rpm.

    70% load is 730 HHP @ 1800 rpm.

    If these limits are exceeded there will be limited warrant.

    For further information please contact Maintenance Diesel Department.