Dimensjoner

  • Lengde(mm):
    2700
  • Bredde(mm):
    1200
  • Høyde(mm):
    1600
  • Vekt (kg):
    3500
  • Løfting/ Transport:
    Frame with forklift pockets and lifting. DNV 2.7-1 Ref. cert. Frame: S 169911 / PP-114

Byggeår

  • Byggeår:
    2015

Bruksområde / Sertifisering

  • Onshore/offshore:

    Offshore

  • Standard:
    Norsok Z-015, Zone 1
  • Drift (Elektrisk/Diesel):

    Elektrisk

Flow / Trykk / Volum

  • Hz v Q-maks måling:
    60
  • Q-max (l/min):
    2600
  • Hz v P-maks måling:
    60
  • P-max (bar):
    30
  • Flowrate1:
    766 ltr/min @ 29,5 bar (60Hz)
  • Flowrate2:
    2000 ltr/min @ 25,03 bar (60Hz)
  • Flowrate3:
    2608 ltr/min @ 20,25 bar (60Hz)

Tilkoblinger

  • Tilkopling inn:
    6” 150# RF, Alternative DN125 CL300
  • Tilkopling ut:
    4” 300# RF, Alternative DN100 CL600

Pumpe(r)

  • Pumpe1 (type):
    KSB Multitec D 100/ 3-7.1 30.63 II 2G c TX
  • Pumpe1 (ser. nr.):
    500086905/001000/02

Motor(er)

  • Motor1 (type):
    Bartec Varnost 4 KTC 315 MB-2 II2G Ex de IIC T4 Cert No: PTB 09 ATEX 1123 X
  • Motor1 (ser. nr.):
    201513940

Strømforsyning

  • Sikring (antall):
    1
  • Sikring (A):
    300
  • Strøm tilkopling 1:
    D 380-415
  • (Hz):
    50
  • (kW):
    160
  • (A):
    266,0
  • Strøm tilkopling 2:
    Y 660-720
  • (Hz):
    50
  • (kW):
    160
  • (A):
    153,5
  • Strøm tilkopling 3:
    D 380-415
  • (Hz):
    60
  • (kW):
    160
  • (A):
    274,0
  • Strøm tilkopling 4:
    Y 660-690
  • (Hz):
    60
  • (kW):
    160
  • (A):
    158,0
  • Strøm tilkopling 5:
    D 440-480
  • (Hz):
    60
  • (kW):
    176
  • (A):
    258,0
  • Kontrollpanel:

    Control cabinet (Ser. No: 76010-EC-002)

    II 2 G EEx de IIB T4

    400-440-480-660-690 50/60 Hz (NEMKO No. 15 ATEX 2121)

Annen informasjon

  • Utstyr / Funksjoner:

    EL. POWER:

    Cable size : Main power 1- P-001 4 G 120 mm²

    Rec. Backup fuse :

    400-480 V: 300 A “slow” fuse (D-characteristic, outlet for motorstarter, circuit-breaker)

    660-690 V: 180 A “slow” fuse (D-characteristic, outlet for motorstarter, circuit-breaker)

    - Pressure gauge on the inlet.

    - Gate valve on outlet

    - Pressure gauge before and after Gate valve on outlet

    - Valve for venting the pump housing.

    - Valve for frost protection in pump.

    - Monitoring phase sequence.

    - Level guard