PUMP FOR PIGGING / CHEMICAL CLEANING
Bruksområde / Sertifisering
Flow / Trykk / Volum
-
Hz v Q-maks måling:
N/A (Diesel)
-
Q-max (l/min):
6200
-
Hz v P-maks måling:
N/A (Diesel)
-
P-max (bar):
28
-
Flowrate1:
1250 ltr/min @ 28 bar
-
Flowrate2:
4250 ltr/min @ 24 bar
-
Flowrate3:
6200 ltr/min @ 17 bar
-
Diesel tankvolum (ltr):
500
-
Dieselforbruk (ltr/time):
85
Tilkoblinger
-
Tilkopling inn:
8” 150# RF
-
Tilkopling ut:
4” 300# RF
Strømforsyning
-
Sikring (antall):
1
-
Sikring (A):
16
-
Strøm tilkopling 1:
230V
-
(Hz):
50/60
-
(A):
10-16
-
Kontrollpanel:
Ceag GHG 6645 (Ser. No: J1972DS) Eexde IIC T6
230 V, 1 phase, 2,5 A, 50/60 Hz
Annen informasjon
-
Utstyr / Funksjoner:
Manometer on pressure side and pressure/vacuum indicator on suction side.
Fixed fire extinguiser PEFS Foam.
Fire extinguisher 12kg.
Signal to platform if:
- Fire and gas alarm.
Air/Diesel supply closes if
- To high r.p.m on motor.
- High exhaust temperature.
- High antifreeze temperature.
- Low oil pressure on motor.
- Low air pressure.
- 20 Lel Gas alarm.
- Fire alarm
- Emergency stop.
- Emergency stop from control room.