Bruksområde / Sertifisering
-
Onshore/offshore:
-
Standard:
Zone 2 ATEX, 80 dBa
Flow / Trykk / Volum
-
Q maks (SCF/H):
180000
-
P-max (bar):
690
-
Diesel tankvolum (ltr):
500
-
Dieselforbruk (ltr/time):
100
Pumpe / Motor
-
Triplex pump:
Hydrarig NP200 1,3" x 1,625"
-
Booster pumpe:
Hydrarig 1,5 x 2,5 x 6
-
Cold-ends:
Hydrarig 1,625"
-
Fordamper:
Hydrarig Pot SN.6851
-
Motor:
Detroit series 60 serial 500 Hk, maks. 2100 rpm. IIA Zone 2 Atex
-
Motor (serienr.):
06R1014711
-
Filter LIN sugeside:
Washable strainer
-
Brann/Gasssentral:
24V DC JCE EEx d IIB T6
-
Signal til plattform ved:
Fire alarm, gas alarm, fault on gas/fire detectors
-
Luft/Diesel tilførsel stenges ved:
- Over racing of motor.
- High temperature on exhaust.
- High temperature on cooling liquid.
- Low oil pressure on motor.
- Low air pressure.
- Fire alarm.
- Shutdown and alarm beacon 20% alarm and shutdown 40% LLG
- Emergency shut-down.
- Emergency shut-down from control room.
- Overpressure nitrogen.
Annen informasjon
-
Utstyr / Funksjoner:
Pump q/w: Foam deluge, OPS connection. Pyrobran
UNIT IS LOCATED IN UK:
Tel: 01224 725599 Fax: 01224 228349
IKM Testing UK Ltd, Peregrine Road, Westhill, AB32 6JL. www.IKM.com