Dimensjoner

  • Lengde(mm):
    4880
  • Bredde(mm):
    2450
  • Høyde(mm):
    2750
  • Vekt (kg):
    13500
  • Løfting/ Transport:
    Frame with forklift channels and lifting slings. DNV 2.7-1
  • Sertifikater / Serie Nr.:
    J5342

Bruksområde / Sertifisering

  • Onshore/offshore:

    Offshore

  • Standard:
    Eexde IIA T3, Zone 2, 80dBa

Flow / Trykk / Volum

  • Q maks (SCF/H):
    180000
  • P-max (bar):
    690
  • Diesel tankvolum (ltr):
    500
  • Dieselforbruk (ltr/time):
    100

Tilkoblinger

  • Tilkopling inn:
    1 ea. Acme 150
  • Tilkopling ut:
    1 ea. 2" Weco Fig. 1502 female / 1” NPTF

Pumpe / Motor

  • Triplex pump:
    Hydrarig NP200 1,3" x 1,625"
  • Booster pumpe:
    Weston 1,5" x 2,5" x 6"
  • Cold-ends:
    Weston 1,625"
  • Fordamper:
    Hydrarig Pot type IPP 00001
  • Motor:
    Detroit diesel 8V-92TA, 480 HP, max 2100 revolutions, IIA T3 Zone II
  • Motor (serienr.):
    8VF144725
  • Filter LIN sugeside:
    Washable strainer
  • Brann/Gasssentral:
    CEAG GHG 6645 II 2(1)G EEx de [ia] IIC T5 (Ser. no. J05 0545/D/M) 230 V 50-60 Hz
  • Signal til plattform ved:
    Firealarm, gas alarm, fault on gas/heatdetector
  • Luft/Diesel tilførsel stenges ved:

    - Over racing of motor.

    - High temperature on exhaust.

    - High temperature on cooling liquid.

    - Low oil pressure on motor.

    - Low air pressure.

    - Fire alarm.

    - Shut down and alarm at 10% LEL gas (CH4)

    - Emergency shut-down.

    - Emergency shut-down from control room.

    - Overpressure nitrogen.

Strømforsyning

  • Sikring (antall):
    1
  • Sikring (A):
    16
  • Strøm tilkopling 1:
    230 V 1 phase (Utility)
  • (Hz):
    50/60

Annen informasjon

  • Utstyr / Funksjoner:

    - Derated capacity : 180.000 SCF/H @ 550 Bar. / 150.000 SCF/H @ 690 Bar

    - Fixed fire extinguiser PEFS Foam.

    - Fire extinguisher 12kg.

    - OPS connection.