Bruksområde / Sertifisering
-
Onshore/offshore:
-
Standard:
Eexde IIA T3, Zone 2
Flow / Trykk / Volum
-
Q maks (SCF/H):
180000
-
P-max (bar):
690
-
Diesel tankvolum (ltr):
500
-
Dieselforbruk (ltr/time):
100
Tilkoblinger
-
Tilkopling inn:
1 ea. Acme 150
-
Tilkopling ut:
1 ea. 1" Weco Fig. 1502
Pumpe / Motor
-
Triplex pump:
NS-181-NF.
CS&P Cryogenics 1,375" x 1,625"
-
Booster pumpe:
CS&P Cryogenics 1,5" x 2,5" x 6"
-
Cold-ends:
CS&P Cryogenics 1,625"
-
Fordamper:
CS&P Cryogenics
-
Motor:
Detroit diesel 8V-92TA 480 HP, max. 2100 revolutions
IIA T3 Zone II
-
Motor (serienr.):
08VF172842
-
Filter LIN sugeside:
Washable strainer
-
Brann/Gasssentral:
Stahl Eexde IIC T5 (Ser. no. 84382)
230 V 1 phase 50/60 Hz
-
Signal til plattform ved:
Gas alarm
-
Luft/Diesel tilførsel stenges ved:
- Over racing of motor.
- High temperature on exhaust.
- High temperature on cooling liquid.
- Low oil pressure on motor.
- Low air pressure.
- Gas alarm.
- Emergency shut-down.
- Emergency shut-down from control room.
- Overpressure nitrogen.
Strømforsyning
-
Sikring (antall):
1
-
Sikring (A):
16
-
Strøm tilkopling 1:
230 V 1 phase (Utility)
-
(Hz):
50/60