Dimensjoner

  • Lengde(mm):
    3200
  • Bredde(mm):
    1250
  • Høyde(mm):
    1800
  • Vekt (kg):
    3000
  • Løfting/ Transport:
    Frame with lifting chain and forklift channels in acc. to DNV 2.7-1 (Ref. cert./Ser. No. : 63576 / 02-07 / PU-24)

Byggeår

  • Byggeår:
    2007

Bruksområde / Sertifisering

  • Onshore/offshore:

    Offshore

  • Standard:
    Eexde IIB T4 Zone 1, in acc. to Norsok Z-015

Flow / Trykk / Volum

  • Tankvolum (ltr):
    800
  • Hz v Q-maks måling:
    60
  • Q-max (l/min):
    2500
  • Hz v P-maks måling:
    60
  • P-max (bar):
    8.5

Tilkoblinger

  • Tilkopling inn:
    2 ea. 2" Camlock Female
  • Tilkopling ut:
    2 ea. 2" Camlock Male

Pumpe(r)

  • Pumpe1 (type):
    KSB CPKN-C1 080-200
  • Pumpe1 (ser. nr.):
    9971116486 00010002

Motor(er)

  • Motor1 (type):
    ATB BD 250M-2 3000/3600rpm EEx de IIB T4 IP56 (Cert. No: PTB 98 ATEX 1107)
  • Motor1 (ser. nr.):
    467377001

Strømforsyning

  • Sikring (antall):
    1
  • Sikring (A):
    125
  • Strøm tilkopling 1:
    400 VD
  • (Hz):
    50
  • (kW):
    55
  • (A):
    95
  • Strøm tilkopling 2:
    690 VY
  • (Hz):
    50
  • (kW):
    55
  • (A):
    55
  • Strøm tilkopling 3:
    400 VD
  • (Hz):
    60
  • (kW):
    55
  • (A):
    97
  • Strøm tilkopling 4:
    440-480 VD
  • (Hz):
    60
  • (kW):
    64
  • (A):
    101-93
  • Strøm tilkopling 5:
    660-690 VY
  • (Hz):
    60
  • (kW):
    55
  • (A):
    59-56
  • Starter:

    CEAG GHG 6655 (Ser. No: J06 0898 /D/M)

    II2G EEx de IIC T6 (Cert. No: PTB 98 ATEX 1054U)

    Nemko No: 06 ATEX 2380

  • Varmeelement:
    Norske Backer IH-Ansi 6”-1000DL (Nemko No: 04 ATEX 1489) 52 kW 3x480V (Recommended back up fuse 63A (Voltage range (400-690 50/60Hz))

Filter

  • Filter inn/retur (antall):
    4
  • Filterhus inn/retur (type):
    Bagfilter (w/4 bag) Type Parker 6SB42-4FK1,SS316
  • Filterelement inn/retur (type):
    BAG 5P2SB

Annen informasjon

  • Utstyr / Funksjoner:

    Recommended back up fuse:

    Motor: 125A

    Heater: 63A (Voltage range (400-690 50/60Hz)

    Other connections :

    2” Camlock Female drain, 1” Camlock Male refill-valve, ½” NPT Female

    Flow switch, steamloop, manhole cover in tank, flowmeter, heater

    Entire unit is built in acid-resistant material.