Dimensjoner

  • Lengde(mm):
    1700
  • Bredde(mm):
    800
  • Høyde(mm):
    1850
  • Vekt (kg):
    600
  • Løfting/ Transport:
    Frame with forklift channels

Byggeår

  • Byggeår:
    1995

Bruksområde / Sertifisering

  • Onshore/offshore:

    Offshore

  • Standard:
    Eexde IIC T4 zone 1, In acc. to Norsok Z-015

Flow / Trykk / Volum

  • Tankvolum (ltr):
    350
  • Hz v Q-maks måling:
    60
  • Q-max (l/min):
    110
  • P-max (bar):
    210
  • Flowrate1:
    45 ltr/min @ 210 Bar (50 Hz)
  • Flowrate2:
    95 ltr/min @ 100 Bar (50 Hz)
  • Flowrate3:
    105 ltr/min @ 50 Bar (50 Hz)
  • Min.viskosiet (cst):
    10
  • Maks. viskositet (cst):
    160
  • Start viskositet (cst):
    1600

Tilkoblinger

  • Tilkopling inn:
    1 ea 1/2" BSP
  • Tilkopling ut:
    1 ea 1/2" BSP

Pumpe(r)

  • Pumpe1 (type):
    Denison PVT-29

Motor(er)

  • Motor1 (type):
    Bartec Varnost 4KTC 180 M-4 II2G EEx de IIC T4 IP56 (Cert. No: PTB 05 ATEX 1054)
  • Motor1 (ser. nr.):
    200833454

Strømforsyning

  • Sikring (A):
    63
  • Strøm tilkopling 1:
    380-415 VD
  • (Hz):
    50
  • (kW):
    18,5
  • (A):
    35,3
  • Strøm tilkopling 2:
    660-720 VY
  • (Hz):
    50
  • (kW):
    18,5
  • (A):
    20,4
  • Strøm tilkopling 3:
    380-415 VD
  • (Hz):
    60
  • (kW):
    18,5
  • (A):
    36,3
  • Strøm tilkopling 4:
    660-690 VY
  • (Hz):
    60
  • (kW):
    18,5
  • (A):
    21
  • Strøm tilkopling 5:
    440-480 VD
  • (Hz):
    60
  • (kW):
    21,3
  • (A):
    35,2
  • Starter:

    Ceag GHG 6645 (Ser. No: 41328)

    Eexde IIC T5 IP-65

    400-690 V 50-60 Hz Max load: 125 A

Filter

  • Filter ut/trykk (antall):
    1
  • Filterhus (type):
    Parker 70T210QBPKG201
  • Filterelement (type):
    D141G03A/P167842/938777Q
  • Filter inn/retur (antall):
    1
  • Filterhus (type):
    Parker RF-22
  • Filterelement (type):
    PARKER 932692Q

Annen informasjon

  • Utstyr / Funksjoner:
    Flowmeter, manometer, level glass, thermometer, sampling