SU-95
STEAMUNIT CLAYTON
Offshore
U05
Water: 1" Offshore claw coupling
Water spark arrestor: 1" Offshore claw coupling
Condensate: 2" Camlock female
Diesel: 1" Camlock female
Steam: 2" Boss Dixon male (mounted in 3" 150# RF)
Drain water tank: 2" Camlock female
Steam drain: 1" Boss Dixon male
Water spark arrestor 1" Offshore claw coupling
The water consumption at full effect is 20% higher then the steam production.
Water consumption unit: 3935 l/h. Spark arrestor: 1140 l/h.
Unit is automodulating between 25 and 100% load.
Sprinkler system: Inergen
Fire and gas central:
STAHL 8264/5224 KEMA 01 ATEX 2145X
Ex II 2 G Ex db eb IIB T4 Gb
Serie nr: 227790-01
Ignition source connection and pressure relief steam if:
-Gas alarm (detector mounted at air inlet).
-Fire alarm.
-Emergency shutdown inside and outside of the container.
-Emergency shutdown from control room.
-Error message from fire/gas central.
Other safety functions:
-Flame detector on burner.
-PT100 element on coil.
-Level monitor in feed water tank.
-Max surface temperature is 200°C.
-Max exhaust temperature is 300°C.