Dimensjoner

  • Lengde(mm):
    4267
  • Bredde(mm):
    2438
  • Høyde(mm):
    3000
  • Vekt (kg):
    10500
  • Løfting/ Transport:
    12" Offshore container with forklift channels and lifting slings. DNV 2.7-1

Bruksområde / Sertifisering

  • Onshore/offshore:

    Offshore

  • Z-015 (type):

    U05

  • Standard:
    Norsok Z-015, CE, Unclassified area, (83 dB)

Teknisk informasjon

  • Boiler:
    Clayton EO-204-2 Ser.no.:B8741
  • Gnistfanger:
    DNV certified. (Ref. cert/Ser. no. : SU-92B)
  • Maksimum Effect (kW):
    1964
  • Maks. steam produksjon (kg/hr):
    3131
  • P-max (bar):
    13
  • P-max (PSI):
    188
  • Maks Steam temperatur (Gr.C):
    195
  • Fødevannstank volum (ltr):
    1800
  • Diesel tankvolum (ltr):
    600
  • Dieselforbruk (ltr/time):
    211

Tilkoblinger

  • Tilkopling inn:

    Water: 1" Offshore claw coupling

    Water spark arrestor: 1" Offshore claw coupling

    Condensate: 2" Camlock female

    Diesel: 1" Camlock female

  • Tilkopling ut:

    Steam: 2" Boss Dixon male (mounted in 3" 150# RF)

    Drain water tank: 2" Camlock female

    Steam drain: 1" Boss Dixon male

    Water spark arrestor 1" Offshore claw coupling

Filter

  • Filterhus inn/retur (type):
    Diesel: 1002MAM10 Water: HECO 899014001
  • Filterelement inn/retur (type):
    Water: PX 2010 Diesel: 2020V30
  • Filterhus ut/trykk (type):
    Diesel: 1002MAM10
  • Filterelement ut/trykk (type):
    Diesel: 2020V30

Strømforsyning

  • Sikring (antall):
    1
  • Sikring (A):
    63
  • Strøm tilkopling 1:
    400-480 V
  • (Hz):
    50/60
  • Strøm tilkopling 2:
    660-690 V
  • (Hz):
    50/60
  • Strøm tilkopling 3:
    230 V
  • (Hz):
    50/60

Annen informasjon

  • Utstyr / Funksjoner:

    The water consumption at full effect is 20% higher then the steam production.

    Water consumption unit: 3935 l/h. Spark arrestor: 1140 l/h.

    Unit is automodulating between 25 and 100% load.

    Sprinkler system: Inergen

    Fire and gas central:

    STAHL 8264/5224 KEMA 01 ATEX 2145X

    Ex II 2 G Ex db eb IIB T4 Gb

    Serie nr: 227790-01

    Ignition source connection and pressure relief steam if:

    -Gas alarm (detector mounted at air inlet).

    -Fire alarm.

    -Emergency shutdown inside and outside of the container.

    -Emergency shutdown from control room.

    -Error message from fire/gas central.

    Other safety functions:

    -Flame detector on burner.

    -PT100 element on coil.

    -Level monitor in feed water tank.

    -Max surface temperature is 200°C.