Dimensjoner

  • Lengde(mm):
    3680
  • Bredde(mm):
    2438
  • Høyde(mm):
    3000
  • Vekt (kg):
    8500
  • Løfting/ Transport:
    12' Offshore container with forklift channels and lifting slings. DNV 2.7-1
  • Sertifikater / Serie Nr.:
    93314 / SU-56

Byggeår

  • Byggeår:
    2009

Bruksområde / Sertifisering

  • Onshore/offshore:

    Offshore

  • Z-015 (type):
    U05
  • Standard:
    Norsok Z-015, CE, Unclassified area, (74 dBa)

Flow / Trykk / Volum

  • Boiler:
    Clayton EO-185-1 (Ser. no: B-7496)
  • Gnistfanger:

    DNV certified. (Ref. cert./Ser. no. : SU-56b)

    Dimension : L 2820mm W 1000mm H 1570mm. Weight : 560 kg

    Lifting/Transport : 2-leg chain sling

  • Maksimum Effect (kW):
    1815
  • Maks. steam produksjon (kg/hr):
    2900
  • P-max (bar):
    10
  • P-max (PSI):
    145
  • Maks Steam temperatur (Gr.C):
    184
  • Fødevannstank volum (ltr):
    1200
  • Diesel tankvolum (ltr):
    600
  • Dieselforbruk (ltr/time):
    210

Tilkoblinger

  • Tilkopling inn:

    Water: 1” Offshore clawcoupling

    Condensate: 2” 150# RF

  • Tilkopling ut:
    Steam: 2” Steam coupling Boss Spud (mounted in 3” 150# RF) Drain, bypass: 3” 150# RF

Filter

  • Filterhus inn/retur (type):
    Feedwater inlet: HECO 899014001 Diesel inlet: RAC
  • Filterelement inn/retur (type):
    Feedwater inlet: PX 2010 Diesel inlet: PF-598-30

Strømforsyning

  • Sikring (antall):
    1
  • Sikring (A):
    63
  • Strøm tilkopling 1:
    400-480 V (main)
  • (Hz):
    50/60
  • (A):
    63 “slow”
  • Strøm tilkopling 2:
    690 V (main)
  • (Hz):
    50/60
  • Strøm tilkopling 3:
    230 V (Utility)
  • (Hz):
    50/60

Annen informasjon

  • Utstyr / Funksjoner:

    High fire steam production : 2900 kg/hour @ 7,5 bar

    Low fire steam production : 1450 kg/hour @ 10 bar

    - The water consumption at full effect is 20% higher than the steam production.

    Sprinkler system : Swordsman foam system.

    Fire, gas central :

    Ceag 664 5002 R1284 EEx de IIC T5 ATEX 2146 (Ser. no. 71705.02)

    Ignition source connection and pressure relief steam if:

    - Gas alarm (Detector mounted at air inlet).

    - Fire alarm.

    - Emergency shut-down on the outside of the container.

    - Emergency shut-down from control room.

    - Error message from fire /gas-central

    Other safety functions :

    - Flame detector on burner.

    - PT 100 element on coil.

    - Level monitor in feed water tank.

    - Max. surface temperature is 200ºC.

    - Max. exhaust temperature is 300ºC.